Sign In | Join Free | My himfr.com
Home > Air Cooled Screw Chiller >

Residential R407C Electric Air Source Heat Pump EKAS085 - EKAS470

Pultruded FRP Online Market
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Residential R407C Electric Air Source Heat Pump EKAS085 - EKAS470 from wholesalers
     
    Buy cheap Residential R407C Electric Air Source Heat Pump EKAS085 - EKAS470 from wholesalers
    • Buy cheap Residential R407C Electric Air Source Heat Pump EKAS085 - EKAS470 from wholesalers

    Residential R407C Electric Air Source Heat Pump EKAS085 - EKAS470

    Ask Lasest Price
    Brand Name : EuroKlimat
    Model Number : EKAS085~EKAS470
    Certification : ARI ,CE,ISO9001,ISO14001,OHSAS18001,CRAA,CQC
    Price : negotiation
    Supply Ability : 10 pcs per month
    Delivery Time : 40 working days after received your payment
    • Product Details
    • Company Profile

    Residential R407C Electric Air Source Heat Pump EKAS085 - EKAS470


    Screw-type air-cooled chilled (heat pump) units


    Overview


    Inheriting the supreme air cooling design from EK Italy and equipped with the leading-edge European design for large-scale air-cooled units, EKAS screw-type air-cooled chilled (heat pump) units feature patented double screw compressors and highefficiency dry evaporators. With optimized system configuration,
    units of this series are efficient, energy saving, reliable, easy to maintain and cost-effective (low operation cost). They are ideal choices for central air conditioning systems of hotels, guest houses, office buildings, schools, hospitals and factories, etc.


    Features


    1.Patent-protected Double Screw Compressor - High Efficiency, Low Noise

    Stepless modulation,Double-layered shell,Simple oil return without oil pump,Patented rotor design,Inlet air filter.


    2.Efficient Heat Exchanger with Outstanding Performance.

    The heat exchanger of EKAS screw-type air-cooled chilled (heat pump) units is EU and ASME certified and features patented refrigerant allocation design. With efficient internalthreaded copper tubes as the heat exchanging medium, the heat exchanger greatly enhances heat transfer between the water and refrigerant, thus lowering power consumption and operation cost.
    ■ To facilitate on-site installation, standard pipe connection for heat exchangers is groove yoke connection (with stub tube). Each evaporator and condenser are equipped with separate
    air and water discharge devices.
    ■ The oil circuit features a simple design (no oil pump) that facilitates oil return to eliminate the risk of freeze-crack on heat exchanging pipes.
    ■ The refrigerant is only 1/3 of that in common heat exchangers, which eliminates the risk of leakage and makes the unit more environment-friendly and reliable.


    3.Reliable and Precise Control by Electronic Expansion Valve

    Full series of units feature electronic expansion valves for optimum superheating control, bringing about high unit performance. With precise PID throttle control by the electronic expansion valve, the refrigerant can be well controlled and outlet air from the compressor can be monitored for compressor protection.


    4.W-shaped Air-side Heat Exchanger for Better Performance.

    The W-shaped air-side heat exchanger features a leading-edge design - coated with wavy aluminum cooling fins and embedded with well-arranged seamless copper tubes with high quality and full mechanical expansion. Even air flow after CAE analysis eliminates interference between the air-side heat exchanger and the fan, bringing about highly efficient heat exchange. Heat exchanger coils are connected to the supercooling circuit (for cooling only units) to avoid too much evaporation of liquid refrigerant, bringing about higher cooling capacity.


    5.Wide Operation Range and Long Service Life

    With shells made from galvanized steel plates and coated with corrosion-proof paint by electrostatic spray, the units are corrosion-proof and adaptable to various harshenvironments.
    ■ Adaptable to wide outdoor temperature range: -15°C ~ 43°C.
    ■ Accurate and efficient auto defrosting and unconditional manual defrosting (if necessary) effectively extend the service life of units.
    ■ By exchange heat directly with the atmosphere, the units are environment friendly and contamination free.


    6.Patented Airscrew Fan - High Air Flow with Low Noise

    Featuring EK low-noise design, the unit fan can effectively prevent air vortex, bringing about higher air flow with little noise.
    ■ The optimum curvy design of impeller edges helps eliminating air vortex, bringing about higher rev and
    efficiency while reducing noise.
    ■ With overheat protection and no racing, the motor features a longer service life.
    ■ The motor features direct transmission to effectively reduce transmission loss and vibration.
    ■ Fan motors with high static pressure are also available for various applications requiring static pressure


    7.Easy Installation, Simple Maintenance

    Power and water are enough to get the unit running. No special equipment room, cooling tower or other auxiliaries are needed.
    ■ Power supply equipment is built into the unit, eliminating the need for complex wiring and special power distribution cabinet.
    ■ The smart control system automatically monitors and controls unit operation, and displays causes of errors to facilitate maintenance.


    8.Compact Structure, Easy Installation

    ■ The unit features a compact structure, integrated startup and control system, extended handle for the general switch, and auto-lock protection after the general switch is closed for safer cabinet door access.
    ■ The whole unit is compact and tidy, featuring a graceful exterior and small volume. This facilitates transportation and reduces the area of equipment room. A little pipelining and wiring are all that needed during installation. Therefore, both installation cost and period are significantly reduced.


    Applications:


    Business Organizations

    supermarket, large-scale shopping malls, exclusive agency, chain shops, large-scale sales, star-rated hotels, restaurants, travel agencies, pharmacy.

    Financial Organizations

    Banks, negotiable securities, funds, insurance companies, pawnshops;

    Non-profit Organizations: Telecommunications, post offices, hospital, schools;

    Public Places

    subway, airports, stations, gas stations, toll stations, bookstores, parks, exhibition halls, stadiums, museums, convention centers, ticket agencies, HR market, lottery centers; Real Estate Property: Apartments, villas, offices, commercial buildings, model rooms, property brokers;

    Entertainments

    Movie theaters, fitness halls, country clubs, clubs, massage rooms, bars, cafes, Internet bars, beauty shops, golf course


    Specification


    Model EKAS085EKAS095EKAS115EKAS125EKAS140EKAS150EKAS165EKAS180
    Nominal cooling capacitykW284.1328.3388.0410.3473.7509.4557.3601.0
    USRT80.893.3110.3116.7134.7144.8158.5170.9
    ×104kcal/h24.428.233.435.340.743.847.951.7
    Nominal heating capacity*kW322.7354.7426.9431.3491.6528.6578.4623.7
    USRT91.8100.9121.4122.6139.8150.3164.4177.3
    ×104kcal/h27.830.536.737.142.345.549.753.6
    Cooling compressor powerkW93.1101.3123.9128.6146.1157.0171.4182.0
    Heating compressor power*kW95.8104.1124.1135.1153.4164.8179.9189.6
    Capacity modulation 25% ~ 100% stepless modulation
    Startup type Y-Δ
    Power supply 380V/3~/50Hz
    RefrigerantType R407C
    Circuit Qty. 11111111
    Control mode Electronic expansion valve
    CompressorType Semi-closed double screw type
    Qty. 11111111
    LubricantCode EK02
    Filling 13x113x113x113x119x119x123x123x1
    FanType Spiral axial fan
    Qty.No.688810101212
    CapacitykW10.814.414.414.418.018.021.621.6
    Air flow×104m3/h1216161620202424
    Air side heat exchangerType Fins
    Densitypiece/inch16FPI
    Water side heat exchangerType Dry shell-tube type
    Water flow for
    cooling
    3
    m /h
    48.956.566.770.681.587.695.9103.4
    Pressure drop of cooling waterkPa5862736466615156
    Water flow for
    heating*
    3
    m /h
    55.561.073.474.284.690.999.5107.3
    Pipe diameterinch45555888
    Rated currentA185207246254292311344362
    Startup currentA250278326338388413455480
    Max. startup currentA357357478478660660749749
    DimensionsLengthmm32004100410041005000500059005900
    Widthmm22602260226022602260226022602260
    Heightmm25252525252525252525252525252525
    Weight of a single indoor unitShipment of cooling only unitskg38654015416547654810481053805500
    Operation of cooling only unitskg40154165431549154966496655405660
    Shipment of heat pump unitskg39504100425048504900490054805600
    Operation of heat pump unitskg41004250440050005056505656405760
               
               
    Model EKAS190EKAS200EKAS210EKAS225EKAS235EKAS250EKAS275EKAS300
    Nominal cooling capacitykW636.4683.3728.2797.2819.9820.6919.71018.7
    USRT181.0194.3207.1226.7233.1233.3261.5289.7
    ×104kcal/h54.758.862.668.670.570.679.187.6
    Nominal heating capacity*kW660.5709.1749.9813.3838.6862.7959.91057.2
    USRT187.8201.6213.2231.2238.4245.3272.9300.6
    ×104kcal/h56.861.064.569.972.174.282.690.9
    Cooling compressor powerkW192.8206.9207.8219.7227.4257.2285.6314.1
    Heating compressor power*kW200.8215.1214.2226.6232.4270.2299.9329.6
    Capacity modulation 25% ~ 100% stepless modulation12.5%~100% stepless modulation
    Startup type Y-Δ
    Power supply 380V/3~/50Hz
    RefrigerantType R407C
    Circuit Qty. 11111222
    Control mode Electronic expansion valve
    CompressorType Semi-closed double screw type
    Qty. 11111222
    LubricantCode EK02
    Filling 23x123x123x123x123x113x219+1319x2
    FanType Spiral axial fan
    Qty.No.1214141616161820
    CapacitykW21.625.225.228.828.828.832.436.0
    Air flow×104m3/h2428283232323640
    Air side heat exchangerType Fins
    Densitypiece/inch16FPI
    Water side heat exchangerType Dry shell-tube type
    Water flow for
    cooling
    3
    m /h
    109.5117.5125.3137.1141.0141.2158.2175.2
    Pressure drop of cooling waterkPa4351567344455364
    Water flow for
    heating*
    3
    m /h
    113.6122.0129.0139.9144.2148.4165.1181.8
    Pipe diameterinch88888888
    Rated currentA381413415446457508565622
    Startup currentA505548549590594676751826
    Max. startup currentA882882882882882732931931
    DimensionsLengthmm59006800680077007700810090009900
    Widthmm22602260226022602260226022602260
    Heightmm25252525252525252525252525252525
    Weight of a single indoor unitShipment of cooling only unitskg55205555575558055835958096759670
    Operation of cooling only unitskg56805715593559856015988099879982
    Shipment of heat pump unitskg56205670587059205950975098509850
    Operation of heat pump unitskg57805830605061006130100501016210162

    Quality Residential R407C Electric Air Source Heat Pump EKAS085 - EKAS470 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Pultruded FRP Online Market
    *Subject:
    *Message: